CVF-300W-L Food Vacuum Rapid Cooler | 300kg/batch · 25–35 min · 90℃→0–8℃
Water-cooled low-temperature food vacuum rapid cooler, 300 kg per batch, cools 80–90℃ hot food to 0–8℃ in 25–35 minutes. Vacuum chamber volume 3.2 m³, c...
CVF-300W-L is the 300 kg water-cooled model in the Vacuum-Fresh rapid cooling line. It loads 300 kg of hot food per batch and cools from a 8090℃ out-of-pot temperature down to 08℃ in 25~35 minutes; the vacuum chamber volume is 3.2 m³, the cooling capacity is 60 kW, and the installed power is 55 kW. In the model code, W indicates a water-cooled condenser and L indicates the low-temperature type.
Where it is used
| Scenario | Typical materials | Description |
|---|---|---|
| Cooked food and braised product processing | Braised beef, braised duck, roast chicken, pig trotters | 300 kg per chamber, chambers opened continuously during the middle shift, no waiting for cooling from out-of-pot to warehousing |
| Central kitchen / group catering | Braised pork, stewed dishes, side dishes, soups | The cooling station no longer blocks the portioning line, multiple batches turned over per shift |
| Prepared dish production lines | Prepared meat products, toppings, soup dishes | Docked with the packaging line, shortening work-in-process time |
| Meat and poultry processing | Roast chicken, roast duck, sausage, ham | Core and surface cool simultaneously, no cold outside and warm inside |
| Bakery plants | Toast, bread, mooncakes | Baked goods have low moisture content (15~45%), less moisture loss, crust less prone to cracking |
How cooling works
Rapid cooling uses two stages, with two vacuum pumps dividing the work; the same pump is not used from start to finish.
| Step | Cooling range | Working parts | Description |
|---|---|---|---|
| 1. High-humidity stage rough pumping | 90℃ → about 50℃ | Water ring pump works alone | The water ring pump withstands high temperature and high humidity, and the circulating water also serves as first-stage water capture |
| 2. Low-temperature stage fine pumping | About 50℃ → 0~8℃ | Rotary vane pump + water catcher | The refrigeration system starts, the water catcher condenses water vapor, and the rotary vane pump draws the chamber pressure down to ≤600 Pa |
| 3. Vacuum breaking and discharge | Target temperature reached | Shutdown and vacuum breaking | After pressure restoration, the door is opened to take out materials and proceed to the next batch |
The water catcher is a prerequisite for this process. Without it, water vapor would enter the rotary vane pump, the pump oil would emulsify, and the vacuum level could not be maintained. Therefore all Vacuum-Fresh rapid coolers are equipped with a refrigeration system as standard, and the water catcher evaporation temperature is uniformly -10~-5℃.
For the capacity tiers and suffix meanings of the entire rapid cooling line, see the product series page.
Technical parameters
Quick specifications:
| Item | Value |
|---|---|
| Model | CVF-300W-L |
| Batch load | 300 kg |
| Cycle time | 25~35 minutes |
| Discharge temperature | 0~8℃ |
| Vacuum chamber volume | 3.2 m³ |
| Condensation method | Water-cooled |
Full parameters:
| Parameter | Value | Remarks |
|---|---|---|
| Model | CVF-300W-L | 300 kg tier, water-cooled condensation, low-temperature type |
| Batch load | 300 kg | — |
| Inlet temperature | 80~90℃ | Loaded into the chamber immediately after coming out of the pot |
| Discharge temperature | 0~8℃ | Low-temperature (L) type |
| Cycle time | 25~35 minutes | Including loading and vacuum breaking |
| Vacuum chamber volume | 3.2 m³ | Processing space specification based on chamber volume |
| Cooling capacity | 60 kW | — |
| Installed power | 55 kW | — |
| Compressor | Copeland scroll compressor ZB150KQE (Copeland) | — |
| Vacuum pump | Leybold SV300B rotary vane pump, pumping speed 300 m³/h, 5.5 kW | Equipped with a water ring pump for first-stage rough pumping |
| Ultimate vacuum | ≤600 Pa | — |
| Water catcher evaporation temperature | -10~-5℃ | Uniform across the system |
| Condensation method | Water-cooled | Model suffix W |
| Refrigerant | R404A / R448A | — |
| Power supply | 3P-380V-50Hz | Voltage for export regions confirmed by order |
| Chamber internal dimensions | Confirmed by order | Related to loading and unloading method |
| Overall weight | Confirmed by order | Related to final configuration |
| Overall dimensions | Confirmed by order | Related to final configuration |
Main configuration list
| No. | Component | Configuration description |
|---|---|---|
| 1 | Compressor | Copeland scroll compressor ZB150KQE (Copeland) |
| 2 | Condenser | Water-cooled shell-and-tube (Lianhe / Kaidi) |
| 3 | Water catcher | Made in-house by Vacuum-Fresh, hot-dip galvanized iron tubes, evaporation temperature -10~-5℃ |
| 4 | Vacuum pump | Leybold SV300B rotary vane pump + water ring vacuum pump |
| 5 | Vacuum chamber | 304 stainless steel welded chamber, volume 3.2 m³ |
| 6 | Chamber door and seal | 304 stainless steel chamber door, food-grade silicone sealing strip |
| 7 | Valves and fittings | Expansion valve TES5-10, filter drier, solenoid valve EVR20, high/low pressure switch KP5 (Danfoss series) |
| 8 | Electrical control system | PLC + touch screen, supports vacuum and temperature setting, automatic cooling program, automatic pump switching, fault alarm |
| 9 | Detection | Vacuum detection system + temperature detection system, linked with the PLC |
| 10 | Cooling water system | Water-cooled piping and valves; cooling tower and circulating water pump provided on site |
Why choose it
- The two pumps each handle one stage. The water ring pump first handles the high-humidity stage from 90℃ to 50℃, and the rotary vane pump only performs low-temperature fine pumping, so the pump oil is less likely to emulsify, and the oil change interval and vacuum stability are more controllable.
- 3.2 m³ chamber, 300 kg per chamber. The main tier for medium-sized cooked food plants and central kitchens; chambers can be opened continuously in a single shift, with no waiting for cooling from out-of-pot to warehousing.
- Water-cooled model, with sufficient margin in hot seasons. The condenser is water-cooled; when the workshop already has a cooling tower and circulating water system, heat dissipation is more stable, making it suitable for southern summers and continuous production conditions.
- Refrigeration system included as standard. The water catcher condenses water vapor at -10~-5℃, so water vapor cannot enter the pump, the chamber pressure stays stable at ≤600 Pa, and results are consistent between batches.
FAQ
How much can CVF-300W-L hold per batch, and how long does it take?
The batch load is 300 kg, and the cycle time is 25~35 minutes, including loading, vacuum pumping, cooling and vacuum breaking for discharge. The time depends on material thickness, moisture content and target temperature; braised products with broth have greater evaporation, so the time will be closer to the upper limit.
What discharge temperature can be reached?
The discharge temperature of the low-temperature (L) type is 0~8℃, settable within the temperature control range. If there is a subsequent cold chain portioning process, the endpoint can be set near 8℃, and the remaining temperature difference can be balanced by the cold storage.
What needs to be provided on site for the water-cooled model?
The site needs to provide circulating cooling water and a cooling tower; the cooling water flow rate is configured according to order requirements, and the inlet water temperature is recommended to be controlled within 32℃; in addition, a three-phase power supply and clean, dry compressed air are required for the pneumatic door and valves. Specific pipe diameters, flow rates and pressures are confirmed item by item during the solution stage.
How are the vacuum pump and water catcher matched?
The vacuum side is two-stage: water ring pump + rotary vane pump. The water ring pump withstands high temperature and high humidity and handles rough pumping from 90℃ to 50℃; the Leybold SV300B rotary vane pump performs fine pumping downstream of the water catcher, drawing the chamber pressure down to ≤600 Pa. The water catcher evaporation temperature is -10~-5℃; it first condenses water vapor, and then the refrigerant carries the heat out of the chamber.
How to choose between it and CVF-500W-L?
CVF-500W-L has a batch load of 500 kg, a vacuum chamber volume of 6.0 m³, a cycle time of 3040 minutes, a discharge temperature of 410℃, a cooling capacity of 95 kW, and an installed power of 75 kW. For a daily processing capacity of around 1 ton, choose CVF-300W-L; for more than two tons, consider the 500 kg tier. For more capacity tiers, see the food vacuum cooler series page.
To check daily processing capacity, cooling water conditions or loading and unloading method, you can first contact us for a selection calculation, or visit the technical library to read the process description of vacuum rapid cooling.
Related technical guides
Vacuum Cooling Cycle Time: How Long from 90°C to 10°C?
A food vacuum chiller runs 15–30 minutes per cycle from 90°C to below 10°C. CVF-200 does 200 kg from 80°C to 0–8°C in 20–30 min; CVF-600 is quoted at 25 min.
Why Two-Stage Vacuum Cooling: Water Ring Pump vs Vane Pump
Food vacuum chillers load at 80–90°C: the ring pump takes 90°C to 50°C, then refrigeration plus the vane pump reach 0–10°C
Refrigeration System Design: Compressor Selection
Engineering guide to compressor selection for vacuum pre-cooling and rapid cooling systems, covering Bitzer