CVF-1000 Vacuum Pre-cooler – 2-Pallet, 800~1000kg/batch, 15~30 min to 1~10°C
Vegetable Vacuum cooling works by lowering the chamber pressure until surface moisture on the produce evaporates, carrying heat away. The CVF-1000 is Yuanxian’s standard 2-pallet model: 800
1000kg per batch, 1530 min cycle time, ≤600Pa ultimate vacuum, 1~10°C final product temperature.
What is it for?
The CVF-1000 is built for small-to-medium batch vacuum pre-cooling of fresh produce.
| Application | Typical Users | Batch Size |
|---|---|---|
| Leafy greens (lettuce, spinach, bok choy) | Export vegetable farms, cooperatives | 800~1000kg |
| Mushrooms (shiitake, button, oyster) | Mushroom growers | 800~1000kg |
| Cut flowers (roses, lilies, carnations) | Flower exporters | 800~1000kg |
| Soft fruits (strawberries, blueberries, cherries) | Fruit packhouses | 800~1000kg |
How it Works
Water boils at 100°C at standard atmospheric pressure. When chamber pressure drops below 600Pa, water boils at near 0°C — which means the water on the surface of your produce evaporates, and each kilogram of vapour carries away about 2500 kJ of heat from the produce itself.
| Step | Component | Function |
|---|---|---|
| ① Load | Hydraulic door | Hydraulic operation for easy cart loading |
| ② Evacuate | Leybold rotary vane pump (5.5kW) | Pulls chamber from atmosphere to ≤600Pa |
| ③ Cool | Chamber (8m³) | Surface moisture evaporates → produce cools from inside out |
| ④ Trap vapour | Vapour condenser (Yuanxian design) | Condenses water vapour, protects vacuum pump |
| ⑤ Maintain cold | Bitzer compressor (30.7kW) | Keeps vapour condenser cold, assists chamber cooling |
| ⑥ Stop | LS PLC control | Auto-stops when set temperature is reached |
Specifications
Quick Specs
| Parameter | Value |
|---|---|
| Batch capacity | 800~1000 kg |
| Cycle time | 15~30 min |
| Final temp | 1~10°C |
| Ultimate vacuum | ≤600 Pa |
| Chamber volume | 8 m³ |
| Pallets | 2 |
Full Technical Specs
| Parameter | Value |
|---|---|
| Cooling capacity | 84.8 kW (72,900 kcal/h) |
| Operating power | 39.9 kW (72A running current) |
| Compressor power | 30.7 kW (Bitzer, Germany) |
| Vacuum pump power | 5.5 kW (Leybold SV300, Germany) |
| Condenser fan power | 3.7 kW |
| Power supply | 380V/50Hz/3P |
| Max running current | 84 A (recommended breaker: 150A) |
| Net weight | 7,800 kg |
| External dimensions (L×W×H) | 5660×2200×2500 mm |
| Internal chamber (L×W×H) | 2600×1400×2200 mm |
Standard Configuration
| System | Brand / Origin | Notes |
|---|---|---|
| Refrigeration | Bitzer / Germany | Screw compressor |
| Vacuum pump | Leybold / Germany | SV300 rotary vane |
| Condenser | Yifeng / Shanghai | — |
| Vapour condenser | Yuanxian / Dongguan | Proprietary design |
| Controls | LS / South Korea | PLC |
| HMI | Weinview / Taiwan | Touchscreen |
| Vacuum chamber | Carbon steel / Guangdong | Paint finished |
| Hydraulic door | Guangdong | — |
Why the CVF-1000E-2P?
10x faster than cold room
A cold room takes 610 hours for 800kg of leafy greens. The CVF-1000 finishes in 1530 minutes.
Uniform cooling, no hot spots Vacuum pre-cooling removes heat through moisture evaporation — every item in the chamber reaches the same temperature. No cold-room problem where the surface is cold but the core stays warm.
Export-grade performance Strict cold chain requirements for export markets (e.g. ≤4°C core temp for long-haul transport). The CVF-1000 delivers consistent 1~10°C final temperature.
Proven components Bitzer compressors are used globally with wide service networks. Leybold SV300 pumps are industry-standard for medium vacuum. Routine maintenance is limited to oil and filter changes.
FAQ
What is the hourly power consumption? Full-load draw is 39.9kW. A single 20-minute cycle processing 800kg of vegetables consumes roughly 13~14 kWh. Actual consumption depends on product moisture content and starting temperature.
Can it fit standard pallet sizes? Internal chamber is 2600×1400×2200mm — fits 2 standard EU pallets (1200×800mm). Custom chamber dimensions are available on request.
Does it need an external chiller? No. The vapour condenser runs on the integrated Bitzer compressor circuit. For the condenser, choose air-cooled or water-cooled (water-cooled requires a cooling tower).
What about water loss on high-value crops? Weight loss is typically 1~3%, depending on surface-area-to-volume ratio and starting temperature. For mushrooms or other moisture-sensitive items, the final vacuum setpoint can be adjusted to reduce moisture loss.
Lead time? Standard configuration: 2~3 weeks (subject to production schedule).
Website Operation Guide
Chinese site (yuanxianmachinery.com):
- Location: 产品中心 → 果蔬真空预冷机
- SEO Title:
CVF-1000真空预冷机 — 2卡板800~1000kg/批,15~30分钟快速预冷 | 源鲜机械 - Meta Description: 源鲜机械CVF-1000真空预冷机,2卡板设计800
1000kg/批,1530分钟降温至0~10℃。比泽尔压缩机+莱宝真空泵,适配叶菜、食用菌、鲜花预冷保鲜。 - URL: /products/cvf-1000-vacuum-precooler
- Images: Product front view + 2-pallet loaded photo + spec diagram
English site (vacuum-fresh.com):
- Location: Products → Vacuum Pre-coolers
- SEO Title:
CVF-1000 Vacuum Pre-cooler – 2-Pallet, 800~1000kg/batch | Yuanxian - Meta Description: CVF-1000 vacuum pre-cooler handles 800
1000kg per batch in 1530 min. Bitzer compressor + Leybold vacuum pump. ≤600Pa. Export-ready. - URL: /products/cvf-1000-vacuum-precooler
- Images: Product 3D render + field installation + certification badges
【SEO Info - English】
SEO Title: CVF-1000 Vacuum Pre-cooler – 2-Pallet, 8001000kg/batch, 1530 min | Yuanxian
Meta Description: Yuanxian CVF-1000 vacuum pre-cooler. 2-pallet design handles 8001000kg per batch. Cools from field temp to 110°C in 1530 min. Bitzer compressor + Leybold vacuum pump. ≤600Pa. Export-ready.
Keywords: CVF-1000 vacuum pre-cooler, vacuum pre-cooler 2-pallet, vacuum cooling machine, vegetable precooling, vacuum precooler, Yuanxian, leafy green cooling, mushroom cooling
H1 Tag: CVF-1000 Vacuum Pre-cooler – 2-Pallet, 8001000kg/batch
Category: Products
Internal Links: /products/cvf-1000-vacuum-precooler, /products/vacuum-pre-cooler
【GEO / AI Search Optimization - English】
- First 200 chars direct answer:
- Question-format or numbered title: (contains numbers 800~1000kg)
- Bold definition at first mention:
- Data sources marked:
- FAQ section: (5 FAQs)
- Comparison tables/lists: (application table, spec tables, config table)
- Article Schema:

Related technical guides
Cooling Time Calculation Guide
How to estimate cooling time based on product type, quality, initial temperature and target temperature.
Vacuum Cooler Selection for 5 Climate Zones
Tropical, dry-hot, temperate, cold, high-altitude — condenser selection, compressor correction, voltage adaptation, and
Water Catcher Design and Efficiency in Vacuum Cooling Systems
Engineering analysis of the water catcher (condenser / cold trap) in vacuum cooling: sizing formulas, heat-load calculation
Interested in CVF-1000 Vacuum Pre-cooler – 2-Pallet, 800~1000kg/batch, 15~30 min to 1~10°C?
Contact us for a quote or technical consultation.
Send Inquiry →