Vegetable Vacuum Cooler Application Technology Analysis

From principle to selection — vacuum level ≤660Pa, 30~50 min/batch, final temp 0~10°C adjustable. Complete vegetable cooling parameter reference table included.

Why Conventional Cooling Falls Short

Leafy greens left at room temperature start wilting after 4-6 hours. A standard cold room takes 8-10 hours to reach 8°C core temperature — by then, the center of the produce is still warm.

Vacuum precooling works differently. Under low pressure, surface moisture evaporates rapidly, absorbing latent heat from the produce itself. Each gram of water evaporated removes approximately 2,260 joules of heat.

How It Works

Key point often misunderstood — the vacuum pump does NOT cool the product. It only removes non-condensable gases. Actual cooling comes from the refrigeration system: water vapor condenses on the cold trap (evaporator at -10°C~-5°C), and the refrigerant cycle expels latent heat.

No defrost cycle needed. Each batch runs 30-50 min, frost buildup is minimal, and the next hot batch naturally melts any residual frost.

CVF Series Specs

Model Capacity Vacuum Batch Time Final Temp
CVF-1000E 2P ≤660Pa 30~40min 0~10°C
CVF-2000E 4P ≤660Pa 35~45min 0~10°C
CVF-3000E 6P ≤660Pa 35~45min 0~10°C
CVF-4000E 8P ≤660Pa 40~50min 0~10°C
CVF-6000 12P ≤660Pa 40~50min 0~10°C

Vegetable Cooling Parameters

Type Cooling Time Moisture Loss
Spinach/Lettuce 25~35min 1.5~2.5%
Head Lettuce 30~40min 1.0~2.0%
Choy Sum/Kai Lan 30~40min 1.5~2.5%
Mushroom 20~30min 0.5~1.5%
Fresh Cut Flowers 20~30min 1.0~2.0%
Strawberry/Blueberry 25~35min 0.5~1.5%

Case Study: Hong Kong Export Farm, Dongguan

CVF-2000E, three months of operation data:

  • Cooling time: 8 hrs → 35 min
  • Spoilage rate: 12% → under 3%
  • Power: ~18 kWh per batch, 60% less than cold room

Yuanxian Machinery — specializing in vegetable vacuum cooling equipment.